IBM Flex System X6 Compute Nodes Product Guide 26
Note: Support by some of these operating system versions will be after the date of initial availability. For
the latest information about the specific versions and service levels that are supported and any other
prerequisites, see the IBM ServerProven® website at:
http://www.ibm.com/systems/info/x86servers/serverproven/compat/us/nos/matrix.shtml
Physical specifications
Dimensions and weight (approximate) for one X6 compute node:
Width: 435 mm (17.1 in.)
Height 56 mm (2.1 in.)
Depth 500 mm (19.7 in.)
Maximum weight: 12.25 kg (27 lbs)
Supported environment
The IBM Flex System X6 Compute Node complies with ASHRAE Class A3 specifications.
This is the supported operating environment:
Power on:
Temperature: 5 to 40 °C (41 to 104 °F)
Humidity, non-condensing: -12 °C dew point (10.4 °F) and 8 - 85% relative humidity
Maximum dew point: 24 °C (75 °F)
Maximum altitude: 3048 m (10,000 ft.)
Maximum rate of temperature change: 5 °C/hr (41 °F/hr)
Power off:
Temperature: 5 to 45 °C (41 to 113 °F)
Relative humidity: 8 - 85%
Maximum dew point: 27 °C (80.6 °F)
Storage (non-operating):
Temperature: 1 to 60 °C (33.8 to 140 °F)
Altitude: 3050 m (10,006 ft.)
Relative humidity: 5 - 80%
Maximum dew point: 29 °C (84.2°F)
Shipment (non-operating):
Temperature: -40 to 60 °C (-40 to 140 °F)
Altitude: 10,700 m (35,105 ft)
Relative humidity: 5 - 100%
Maximum dew point: 29 °C (84.2 °F)
Comments to this Manuals