IBM x Series 200 User Manual Page 108

  • Download
  • Add to my manuals
  • Print
  • Page
    / 152
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 107
100 Hardware Maintenance Manual: xSeries 200
ServeRAID
For ServeRAID error codes and procedures, refer to the Hardware Maintenance
Manual for the particular RAID adapter in the system being serviced.
Undetermined problems
You are here because the diagnostic tests did not identify the failure, the Devices List
is incorrect, or the system is inoperative.
Note: A corrupt CMOS can cause undetermined problems.
If power problems are suspected:
1. Power-off the computer.
2. Be sure the system is cabled correctly.
3. Remove or disconnect the following (one at a time) until you find the failure
(power-on the computer and reconfigure each time).
Any external devices
Surge suppressor device (on the computer)
Modem, printer, mouse, or non-IBM devices
Each adapter
Drives
Memory Modules (Minimum requirement = one 128 MB DIMM)
Note: Minimum operating requirements are:
a. 1 Power Supply
b. System Board
c. 1 Microprocessor
d. 1 Terminator Card in Slot 2
e. 1 Memory Module (minimum of 1 DIMM in slot labeled DIMM 1)
4. Power-on the computer. If the problem remains, suspect the following FRUs in
the order listed:
Power Supply
System Board
Notes:
1. If the problem goes away when you remove an adapter from the system, and
replacing that adapter does not correct the problem, suspect the system board,
then the power supply.
2. If you suspect a networking problem and all the system tests pass, suspect a
network cabling problem external to the system.
Page view 107
1 2 ... 103 104 105 106 107 108 109 110 111 112 113 ... 151 152

Comments to this Manuals

No comments