IBM 3650 M4 User's Guide

Browse online or download User's Guide for Servers IBM 3650 M4. IBM System x 3650 M4 User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 51
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
IBM System x3650 M4 1
I B M ®
IBM System x3650 M4
IBM Redbooks Product Guide
The IBM® System x3650 M4 server provides outstanding performance for your business-critical
applications. Its energy-efficient design supports more cores, memory, and data capacity in a scalable 2U
package that is easy to service and manage. With more computing power per watt and the latest Intel
Xeon processors, you can reduce costs while maintaining speed and availability.
Suggested use: database, virtualization, enterprise applications, collaboration/email, streaming media,
web, HPC, Microsoft RemoteFX, and cloud applications.
Figure 1 shows the IBM System x3650 M4.
Figure 1. The IBM System x3650 M4
Did you know?
The x3650 M4 offers a flexible, scalable design and simple upgrade path to 16 hard-disk drives (HDDs) or
solid-state drives (SSDs) plus optical and tape drives at the same time, with up to six PCIe Gen 3 slots
and up to 768 GB of memory. This flexible onboard Ethernet solution provides four standard embedded
Gigabit Ethernet ports and two optional embedded 10 Gb Ethernet ports without occupying PCIe slots.
Comprehensive systems management tools with the next-generation Integrated Management Module II
(IMM2) make it easy to deploy, integrate, service, and manage.
Page view 0
1 2 3 4 5 6 ... 50 51

Summary of Contents

Page 1 - I B M ®

IBM System x3650 M4 1I B M ®IBM System x3650 M4IBM Redbooks Product GuideThe IBM® System x3650 M4 server provides outstanding performance for your bu

Page 2 - Key features

IBM System x3650 M4 10Express modelsThe following table lists the express models.Table 3. Express models (Part 1)Model Processor Memory RAIDcontroller

Page 3 - IBM System x3650 M4 3

IBM System x3650 M4 11Table 3. Express models (Part 2)Model Processor Memory RAIDcontrollerDiskbaysDisks GbE Slots Optical PowerCentral and Eastern Eu

Page 4 - IBM System x3650 M4 4

IBM System x3650 M4 12Processor optionsThe x3650 M4 supports the processor options listed in the following table. The server supports up to two proces

Page 5 - IBM System x3650 M4 5

IBM System x3650 M4 13Maximum number of ranks per one channel is eight (with the exception of Load Reduced DIMMs where more than eight ranks are supp

Page 6 - Standard specifications

IBM System x3650 M4 14Table 5. Maximum memory speeds (Part 2: HyperCloud DIMMs and LRDIMMs)DIMM specification HyperCloud DIMM LRDIMMRank Dual rank Qua

Page 7

IBM System x3650 M4 15The following table lists the memory options that are available for x3650 M4 server.Table 6. Memory optionsPart numberFeature co

Page 8 - Standard models

IBM System x3650 M4 16Internal disk storage optionsIBM System x3650 M4 server supports 1.8-inch solid-state drives (SSDs), 2.5-inch SSDs and HDDs, and

Page 9 - IBM System x3650 M4 9

IBM System x3650 M4 17Backplanes and enablement kitsAll standard models, except model C4x, ship with eight 2.5" Slim-SFF SAS/SATA hot-swap hard d

Page 10 - Express models

IBM System x3650 M4 18Use the following table to determine what backplane kits you need.Table 8. Drive combinationsDrive combination Configure these k

Page 11 - IBM System x3650 M4 11

IBM System x3650 M4 19RAID controllersThe following table lists the RAID controllers and additional options used for internal disk storage of x3650 M4

Page 12 - Memory options

IBM System x3650 M4 2Key featuresThe x3650 M4 is an outstanding 2U two-socket business-critical server, offering improved performance and pay-as-you g

Page 13 - ** NS = Not Supported

IBM System x3650 M4 20The integrated ServeRAID M5110e SAS/SATA Controller has the following specifications:Two Mini-SAS internal connectors Supports

Page 14 - IBM System x3650 M4 14

IBM System x3650 M4 21The following table lists hard drive options for the internal disk storage of the x3650 M4 server. Table 10. Disk drive options

Page 15 - Table 6. Memory options

IBM System x3650 M4 22Table 10. Disk drive options for internal disk storage (Part 2)Part number FeaturecodeDescription Maximumsupported2.5" SAS

Page 16 - Internal disk storage options

IBM System x3650 M4 23Internal backup unitsThe server supports the internal tape drive options listed in the following table. The x3650 M4 Tape Enable

Page 17

IBM System x3650 M4 24Optical drivesThe server supports the optical drive options listed in the following table.Table 12. Optical drivesPart number Fe

Page 18 - Table 8. Drive combinations

IBM System x3650 M4 25I/O expansion optionsThe server supports up to six PCIe slots with different riser cards installed into two riser sockets on the

Page 19 - M4 server

IBM System x3650 M4 26The specific slots that are available depend on the riser cards installed in Riser socket 1 and Riser socket 2, as shown in the

Page 20 - IBM System x3650 M4 20

IBM System x3650 M4 27Table 15. Network adapters (Part 2)Part number FeaturecodeDescription Maximumsupported#10 Gb Ethernet49Y7910 A18Y Broadcom NetXt

Page 21

IBM System x3650 M4 28Storage host bus adaptersThe following table lists storage HBAs supported by x3650 M4 server. The maximum quantity listed is for

Page 22

IBM System x3650 M4 29PCIe SSD adaptersThe server supports the High IOPS SSD adapters listed in the following table. Table 17. SSD adaptersPart number

Page 23 - Internal backup units

IBM System x3650 M4 3Availability and serviceabilityThe x3650 M4 provides many features to simplify serviceability and increase system uptime: The ser

Page 24 - Optical drives

IBM System x3650 M4 30Power suppliesThe server supports up to two redundant power supplies. Standard models come with one or two power supplies (mode

Page 25 - I/O expansion options

IBM System x3650 M4 31Remote managementThe server contains IBM Integrated Management Module II (IMM2), which provides advanced service-processor contr

Page 26 - Network adapters

IBM System x3650 M4 32Supported operating systemsThe server supports the following operating systems:Microsoft Windows Server 2012Microsoft Windows S

Page 27

IBM System x3650 M4 33Physical and electrical specificationsDimensions and weight:Height: 86.5 mm (3.4 in)Width: 445 mm (17.5 in)Depth: 746 mm (29.4

Page 28 - Storage host bus adapters

IBM System x3650 M4 34BTU output:Minimum configuration: 525 Btu/hr (123 watts)Maximum configuration: 3480 Btu/hr (1020 watts)Noise level:6.6 bels

Page 29 - GPU adapters

IBM System x3650 M4 35In general, the types of IBM ServicePacs are as follows:Warranty and maintenance service upgrades:One, 2, 3, 4, or 5 years of 9

Page 30 - Integrated virtualization

IBM System x3650 M4 36External disk storage expansionThe x3650 M4 supports attachment to external storage expansion enclosures, such as the EXP2500 se

Page 31 - Remote management

IBM System x3650 M4 37The ServeRAID M5120 SAS/SATA Controller supports connectivity to the IBM System Storage external expansion enclosures listed in

Page 32 - Supported operating systems

IBM System x3650 M4 38The following table lists the drives supported by EXP2512 external expansion enclosures.Table 26. Drive options for EXP2512 exte

Page 33 - IBM System x3650 M4 33

IBM System x3650 M4 39External disk storage systemsThe following tabel lists the external storage systems that are supported by x3650 M4 and can be or

Page 34 - Warranty options

IBM System x3650 M4 4Energy efficiencyThe x3650 M4 offers the following energy-efficiency features to save energy, reduce operational costs, increase

Page 35 - Regulatory compliance

IBM System x3650 M4 40External backup unitsThe server supports the external backup attachment options that are listed in the following table.Table 29.

Page 36 - IBM System x

IBM System x3650 M4 41Table 29. External backup options (Part 2)Part number DescriptionExternal backup units*362516X IBM RDX Removable Hard Disk Stora

Page 37

IBM System x3650 M4 42Top-of-rack Ethernet switchesThe server supports the top-of-rack Ethernet switches from IBM System Networking listed in the foll

Page 38

IBM System x3650 M4 43Uninterruptible power supply unitsThe server supports attachments to the uninterruptible power supply (UPS) units listed in the

Page 39 - External disk storage systems

IBM System x3650 M4 44Power distribution unitsThe server supports attachments to the power distribution units (PDUs) listed in the following table. Ta

Page 40 - External backup units

IBM System x3650 M4 45Table 32. Power distribution units (part 2)Part number DescriptionUniversal PDUs39Y8951 DPI Universal Rack PDU with US LV and HV

Page 41

IBM System x3650 M4 46Rack cabinetsThe server supports the rack cabinets listed in the following table. Table 33. Rack cabinetsPart number Description

Page 42 - Top-of-rack Ethernet switches

IBM System x3650 M4 47Rack optionsThe server supports the rack console switches and monitor kits listed in the following table. Table 34. Rack options

Page 43

IBM System x3650 M4 48IBM Global FinancingIBM Global Financing can help you obtain the IT solution you need while preserving funding for other strateg

Page 44 - Power distribution units

IBM System x3650 M4 49Related publications and linksFor more information, see these resources:IBM System x3650 M4 product pagehttp://www.ibm.com/syst

Page 45

IBM System x3650 M4 5Figure 3 shows the rear of the server.Figure 3. Rear view of the IBM System x3650 M4Figure 4 shows the locations of key component

Page 46 - Rack cabinets

IBM System x3650 M4 50NoticesThis information was developed for products and services offered in the U.S.A.IBM may not offer the products, services, o

Page 47 - Rack options

IBM System x3650 M4 51This document was created or updated on March 15, 2013.Send us your comments in one of the following ways:Use the online Contact

Page 48 - IBM Global Financing

IBM System x3650 M4 6Standard specificationsThe following table lists the standard specifications. Table 1. Standard specifications (part 1)Components

Page 49 - IBM System x3650 M4 49

IBM System x3650 M4 7Table 1. Standard specifications (part 2)Components SpecificationCooling IBM Calibrated Vectored Cooling™ with up to four redunda

Page 50

IBM System x3650 M4 8Standard modelsThe following table lists the standard models.Table 2. Standard modelsModel Intel Xeon processors†(two maximum)Mem

Page 51 - Trademarks

IBM System x3650 M4 9Workload optimized model - SAP Discovery systemModel GSx comes preinstalled with SAP Discovery system V5. The SAP Discovery syste

Comments to this Manuals

No comments