Page view 439
Chapter 7: Collection Formulas
418 Netcool/Proviso Cisco IP Telephony Technology Pack User’s Guide, Version 4.3-W
Total Number of Outgoing External Calls (Nb)
Type
CME
Description
The total number of outbound calls going to the PSTN.
An outgoing external call can be any of these call types:
•Local
Long distance
International
This metric is a subset of the Cluster Total Number of External Calls (Nb).
Syntax
^(Local + International + LongDistance)
Formula Input
Input: International
Source: International (Formula)
Input: Local
Source: Local (Formula)
Input: LongDistance
Source: LongDistance (Formula)
Generic Database Alias
None.
Formula Editor Path
AP > Specific > CME > VOIP > Cisco