IBM System x3250 M2 Types 4190 and 4194User’s Guide
Statement 2: CAUTION: When replacing the lithium battery, use only IBM Part Number 33F8354 or an equivalent type battery recommende
Statement 3: CAUTION: When laser products (such as CD-ROMs, DVD drives, fiber optic devices, or transmitters) are installed, note t
Statement 4: ≥ 18 kg (39.7 lb) ≥ 32 kg (70.5 lb) ≥ 55 kg (121.2 lb) CAUTION: Use safe practices when lifting. Statemen
Statement 8: CAUTION: Never remove the cover on a power supply or any part that has the following label attached. Hazardous vol
xii IBM System x3250 M2 Types 4190 and 4194: User’s Guide
Chapter 1. The System x3250 M2 Types 4190 and 4194 The IBM System x3250 M2 Type 4190 or 4194 server is a 1-U-high server that
device drivers, and operating systems. The System x and xSeries Tools Center is at http://publib.boulder.ibm.com/infocenter/toolsctr/v1r0
Features and specifications The following information is a summary of the features and specifications of the server. Depending on the
Table 1. Features and specifications Microprocessor:One Intel® LGA 775 single core, dual core, or quad core, depending on the server m
What your server offers The server uses the following features and technologies: v Baseboard management controller The baseboard mana
v Dynamic System Analysis (DSA) Preboot diagnostic programs The DSA diagnostic programs are provided on the Dynamic System Analysis
v System error logs v Vital product data (VPD); includes information stored in nonvolatile memory for easier remote viewing v W
The UpdateXpress program The UpdateXpress program is available for most System x servers and optional devices. It detects supported a
Locator LED: This LED can be lit remotely by the system administrator to aid in visually locating the server. You can use IBM Di
Systems-management connector: Connect the server to a network for systems-management information control. This connector is active only
Statement 5: CAUTION: The power control button on the device and the power switch on the power supply do not turn off the elect
12 IBM System x3250 M2 Types 4190 and 4194: User’s Guide
Chapter 2. Installing optional devices This chapter provides detailed instructions for installing optional hardware devices in the serv
2.5-inch models Riser-cardAssemblySAS/SATA controller(some models)System boardPower supplyFansBezelCD/DVDdriveFansAir baffleMicroprocessorDIMMOperato
System-board internal connectors The following illustration shows the internal connectors on the system board. SAS/SATA controllercard con
IBM System x3250 M2 Types 4190 and 4194User’s Guide
System-board switches and jumpers The following illustration shows the switches and jumpers on the system board. Boot blockrecovery jump
System-board external connectors The following illustration shows the external connectors on the system board. DIMM 1 SlotDIMM 2 SlotDIMM
System-board LEDs The following illustration shows the light-emitting diodes (LEDs) on the system board. Standbypower LEDDIMM 4error LEDDIM
System-board optional-device connectors The following illustration shows the connectors for user-installable optional devices. Remote Super
The following illustration shows the location of the PCI-X slot on the optional PCI-X riser-card assembly.PCI-X slotPower cable Instal
v Do not attempt to lift an object that you think is too heavy for you. If you have to lift a heavy object, observe the fol
Working inside the server with the power on Attention: Static electricity that is released to internal server components when the s
2. Turn off the server and all attached devices (see “Turning off the server” on page 10). 3. Disconnect all external cables a
connectors” on page 19 for the location of the connector). To install the Remote Supervisor Adapter II SlimLine, see “Installing a
PCI-X slotPower cable4. If the riser-card assembly is an optional PCI-X riser-card assembly, disconnect the riser-card power cable fr
Note: Before using this information and the product it supports, read the general information in “Notices,” on page 57 and the War
AdapterAdapterbracketExpansion-slotbracketTabImportant: Make sure that the U-shaped opening in the metal adapter bracket engages the tab
J8J9ServeRAID controllerHard disc drivebackplaneIf you have other devices to install or remove, do so now. Otherwise, go to “Completing
Remote Supervisor Adapter II SlimLineMounting bracketMounting bracketMounting bracketretention latch1. Read the safety information that begin
8. Press the Remote Supervisor Adapter II SlimLine firmly into the connector and make sure that all tabs on both mounting bracke
Installing a simple-swap Serial ATA hard disk drive Attention: Simple-swap hard disk drives are not hot-swappable. Disconnect all pow
4. Pull the loops of the drive tray toward each other and pull the tray out of the bay.Installing a hot-swap hard disk drive T
b. Align the drive assembly with the guide rails in the bay. c. Gently push the drive assembly into the bay until the drive
Alignment pinsDrive retention clip4. Remove the retention clip from the drive and save it for future use.To install a CD or DVD d
4. Install the PCI-X riser-card power cable. a. Separate the P4 connector on the cable that connects the power supply to the
6. Install a PCI-X or PCI adapter, if you have one available: a. Remove the expansion-slot cover from the PCI-X slot on the
Contents Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . .v Chapter 1. The System x3250 M2 Types 4190
PCI-X slotPower cable8. Connect the riser-card power cable to the PCI-X riser-card assembly.If you have to remove the PCI-X riser-c
v When you restart the server after you add or remove a DIMM, a message is displayed indicating that the memory configuration h
Completing the installation To complete the installation, complete the following steps: 1. Reinstall the cover. See “Installing the
RearPower-cord connectorSerial connectorVideo connectorEthernet 2 connectorEthernet 1 connectorUSB 3 connectorUSB 4 connectorSystems-managementconnect
40 IBM System x3250 M2 Types 4190 and 4194: User’s Guide
Chapter 3. Configuring the server The following configuration programs come with the server: v IBM ServerGuide Setup and Installatio
v IBM Director IBM Director is a workgroup-hardware-management tool that you can use to centrally manage System x servers. If you
Setup and configuration overview When you use the ServerGuide Setup and Installation CD, you do not need setup diskettes. You can u
4. From the Task menu, select Install. 5. From the Product family menu, select System x3250 M2. 6. From the Operating system
v Devices and I/O Ports Select this choice to view or change assignments for devices and input/output (I/O) ports, to configure r
Configuring the controller and devices . . . . . . . . . . . . . . .51 Using the baseboard management controller . . . .
example, you can define a startup sequence that checks for a CD or DVD in the CD or DVD drive, then checks the hard disk drive
- System-BMC Serial Port SharingSelect this choice to specify whether the serial port that the BMC uses is shared with the rest
– RSA II Event/Error LogThis choice is displayed only when a Remote Supervisor Adapter II SlimLine is installed in the server. Se
If a power-on password is set, you can enable the Unattended Start mode, in which the keyboard and mouse remain locked but the o
DIMM 1 SlotDIMM 2 SlotDIMM 3 SlotDIMM 4 SlotClear CMOS jumperSAS/SATAcontrollercardTo clear CMOS and reset the passwords, complete the follow
2. When the prompt Press CTRL-H to start WebBIOS Configuration Utility... is displayed, press Ctrl+H. If you have set an administ
v Spin-up properties v PHY propertiesUsing the baseboard management controller The mini-baseboard management controller provides basi
The installation program prompts you for a TCP/IP port number and an IP address. Specify an IP address, if you want to limit the
1. Insert the configuration utility diskette into the diskette drive and restart the server. 2. From a command-line prompt, type
v reboot Force the server to restart. v sel Perform operations with the BMC system-event log. v sensor Display a list of suppor
Safety Before installing this product, read the Safety Information. Antes de instalar este produto, leia as Informações de Seguranç
b. If a newer version of IBM Director than what comes with the server is shown in the drop-down list, follow the instructions
Appendix. Notices This information was developed for products and services offered in the U.S.A. IBM may not offer the products, ser
Active PCI-X Predictive Failure Analysis XA-64 AIX ServerGuide X-Architecture Alert on LAN ServerProven XpandOnDemand BladeCenter System
Maximum memory might require replacement of the standard memory with an optional memory module. IBM makes no representation or warran
Remarque : Cette marque s’applique uniquement aux pays de l’Union Européenne et à la Norvège. L’etiquette du système respecte la Dir
Notice: This mark applies only to countries within the European Union (EU). Batteries or packaging for batteries are labeled in acc
German Ordinance for Work gloss statement The product is not suitable for use with visual display work place devices according to c
European Union EMC Directive conformance statement This product is in conformity with the protection requirements of EU Council Direct
Japanese Voluntary Control Council for Interference (VCCI) statement Korean Class A warning statement 64 IBM System x3250 M2 Ty
Index Aadapterinstalling 23 PCI Express bus 23 administrator password 45, 49 attention notices 2 Bbaseboard management controller utility
Antes de instalar este producto, lea la información de seguridad. Läs säkerhetsinformationen innan du installerar den här produkten.
hard disk drive (continued)SCSISee SAS simple-swap SATA 30 heat output 4 humidity 4 IIBM Director 5, 7, 55 important notices 2 installa
serial connector 9 ServeRAID 5 ServerGuideCD 5 features 42 NOS installation 43 setup 43 using 42 setting clear CMOS (password override)
68 IBM System x3250 M2 Types 4190 and 4194: User’s Guide
Part Number: 44R5195 Printed in USA (1P) P/N: 44R5195
Statement 1: DANGERElectrical current from power, telephone, and communication cables is hazardous. To avoid a shock hazard: v Do
Comments to this Manuals