IBM 258262U Datasheet Page 22

  • Download
  • Add to my manuals
  • Print
  • Page
    / 25
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 21
IBM System x3100 M4 22
Supported environment:
Temperature
Server on
10.0° to 35.0° C (50° to 95° F); altitude: 0 to 914.4 m (3,000 ft)
10.0° to 32.0° C (50° to 89.6° F); altitude: 914.4 m (3,000 ft) to 2,133.6 m (7,000 ft)
Server off
10.0° to 43.0° C (50° to 109.4° F); maximum altitude: 2,133.6 m (7,000 ft)
Shipping
-40° to 60° C (-40° to 140° F)
Relative humidity: 8 to 80%
Maximum altitude: 2,133.6 m (7,000 ft)
Electrical:
100 - 127 (nominal) V ac; 50 - 60 Hz; 7.0 A
200 - 240 (nominal) V ac; 50 - 60 Hz; 3.5 A
Input kilovolt-amperes (kVA) (approximately)
Minimum configuration: 0.095 kVA
Maximum configuration: 0.435 kVA
Btu output
Ship configuration: 324 Btu/hr (95 watts)
Full configuration: 1484 Btu/hr (435 watts)
Noise level
4.5 bels (idle)
4.8 bels (operating)
Regulatory compliance
The server conforms to the following international standards:
FCC - Verified to comply with Part 15 of the FCC Rules, Class A
Canada ICES-003, issue 4, Class A
UL/IEC 60950-1
CSA C22.2 No. 69950-1-03
NOM-019
Argentina IEC60950-1
Japan VCCI, Class A
Australia/New Zealand AS/NZS CISPR 22:2009, Class A
IEC-60950-1:2001 (CB Certificate and CB Test Report)
Taiwan BSMI CNS 13438, Class A; CNS 14336
China CCC (4943-2001), GB 9254-2008 Class A, GB 17625.1:2003
Korea KN22, Class A; KN24
Russia/GOST ME01, IEC-60950-1, GOST R 51318.22-99, GOST R 51318.24-99, GOST R
51317.3.2-2006, GOST R 51317.3.3-99
IEC 60950-1 (CB Certificate and CB Test Report)
CE Mark (EN55022 Class A, EN60950-1, EN55024, EN61000-3-2, EN61000-3-3)
CISPR 22, Class A
TUV-GS (EN60950-1 /IEC60950-1,EK1-ITB2000)
Page view 21
1 2 ... 17 18 19 20 21 22 23 24 25

Comments to this Manuals