IBM T200F User Manual Page 36

  • Download
  • Add to my manuals
  • Print
  • Page
    / 126
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 35
Sequential Access Device Log
The Sequential Access Device Log Page is 0Ch.
Table 21. Sequential Access Device Log Parameters
Parameter Description Length DU LP LBIN
0h Write Data Bytes
Received, before
compression
8000
1h Write Data Bytes
Received, after
compression
8000
2h Read Data Bytes Sent,
before compression
8000
3h Read Data Bytes Sent,
after compression
8000
0100h Cleaning Required 8000
8000h Megabytes processed
since last cleaning
4000
8001h Lifetime load cycles 4000
8002h Lifetime cleaning cycles 4000
A non-zero value of the Cleaning Required parameter indicates that a condition
requiring cleaning has been detected and a subsequent cleaning cycle has not
been completed. The Cleaning Required parameter is persistent across hard resets
and power cycles.
22 Ultrium Internal Tape Drive and 3580 Ultrium Tape Drive: SCSI Reference