IBM 1000VA and 1500VA LCD Tower UPS 1
򔻐򗗠򙳰 ®
IBM 1000VA and 1500VA LCD Tower UPS
IBM System x at-a-glance guide
The IBM 1000VA and 1500VA LCD Tower Uninterruptible Power Supply (UPS) offerings provide power
protection with increased efficiency and simplified power management to safeguard high-availability IBM
System x server environments. With efficiency ratings of 95% or greater, these compact tower designs
can help reduce energy usage without compromising performance or reliability.
The IBM LCD Tower UPS is shown in Figure 1.
Figure 1. IBM LCD Tower Uninterruptible Power Supply
Did You Know?
The IBM 1000VA and 1500VA LCD Tower UPS offerings have a bright, easily customizable, and
graphical LCD display that lets you configure the device and displays important UPS status information in
one of nine languages.
These units can also enhance system availability with intelligent individual receptacle groups or load
segments that can be programmed and controlled, allowing mission-critical devices to be prioritized
during shutdown to preserve battery run time in the event of a prolonged power outage.
Additionally, these units come equipped with a communication bay that allows the installation of an
optional network management card (46M4110). The network management card provides convenient
over-the-network UPS remote monitoring and management through a standard web browser. This
solution features advanced capabilities, such as secure, remote flash upgradeable firmware for both the
UPS and network management card, which makes it an ideal solution for remote locations.
Page view 0
1 2 3 4 5 6 ... 20 21

Summary of Contents

Page 1 - Did You Know?

IBM 1000VA and 1500VA LCD Tower UPS 1򔻐򗗠򙳰 ®IBM 1000VA and 1500VA LCD Tower UPSIBM System x at-a-glance guideThe IBM 1000VA and 1500VA LCD Tower Uninter

Page 2 - Part number information

IBM 1000VA and 1500VA LCD Tower UPS 10The buttons have the following functions:Escape (X): Press this button to return to the previous menu without ru

Page 3 - Table 2. Supplied line cords

IBM 1000VA and 1500VA LCD Tower UPS 11Figure 4 shows the rear panel of the 120 V models of the IBM 1000VA LCD Tower UPS (53961AX) and IBM 1500VA LCD T

Page 4

IBM 1000VA and 1500VA LCD Tower UPS 12Network Management CardThe IBM 1000VA and 1500VA LCD Tower UPS models also come equipped with a communication ba

Page 5 - Features

IBM 1000VA and 1500VA LCD Tower UPS 13Figure 6 shows the Network Management Card UPS properties window. Figure 6. IBM LCD UPS Network Management Card

Page 6 - Specifications

IBM 1000VA and 1500VA LCD Tower UPS 14IBM UPS Manager softwareThe UPS comes with the IBM UPS Manager software. The management software provides up-to-

Page 7

IBM 1000VA and 1500VA LCD Tower UPS 15Figure 8 shows that the utility power supply has failed and that the UPS is now operating on battery. The UPS Ma

Page 8 - Front panel controls

IBM 1000VA and 1500VA LCD Tower UPS 16Figure 9 shows the event notification window where you can configure how you (and other users) want to be notifi

Page 9

IBM 1000VA and 1500VA LCD Tower UPS 17IBM Environmental Monitoring Probe The Environmental Monitoring Probe (EMP) (part number 46M4113) is used to re

Page 10 - Rear panel

IBM 1000VA and 1500VA LCD Tower UPS 18Figure 11. Environmental Monitoring Probe data as viewed from the Network Management Card web interfaceIBM Syste

Page 11

IBM 1000VA and 1500VA LCD Tower UPS 19Related publicationsFor more information about this topic, refer to these documents:IBM US Product Announcement

Page 12 - Network Management Card

IBM 1000VA and 1500VA LCD Tower UPS 2About uninterruptible power suppliesAn uninterruptible power supply (UPS) is a device that acts as a defensive ba

Page 13

IBM 1000VA and 1500VA LCD Tower UPS 20NoticesThis information was developed for products and services offered in the U.S.A.IBM may not offer the produ

Page 14 - IBM UPS Manager software

IBM 1000VA and 1500VA LCD Tower UPS 21This document was created or updated on January 18, 2011.Send us your comments in one of the following ways:Use

Page 15

IBM 1000VA and 1500VA LCD Tower UPS 3Table 2. Supplied line cordsDescription Part number Supplied line cordIBM 1000VA LCD Tower UPS (100 V) 53961JX IE

Page 16

IBM 1000VA and 1500VA LCD Tower UPS 4Table 3. Line cords for 230 V models (models 53961KX and 2KX)230V line cords - 2.8 m line cords Part numberEurope

Page 17

IBM 1000VA and 1500VA LCD Tower UPS 5FeaturesThe IBM 1000VA and 1500VA LCD Tower UPS offerings include the following features and capabilities:Compact

Page 18

IBM 1000VA and 1500VA LCD Tower UPS 6SpecificationsTable 4 lists the specifications for the IBM 1000VA and 1500VA LCD Tower UPS models.Table 4. Specif

Page 19 - Related publications

IBM 1000VA and 1500VA LCD Tower UPS 7Table 4. Specifications (continued)Specification IBM 1000VA LCD Tower UPS (100 V)IBM 1000VA LCD Tower UPS (120 V)

Page 20

IBM 1000VA and 1500VA LCD Tower UPS 8Table 6 lists the expected period that the IBM 1500VA LCD Tower UPS models will operate solely on batteries. Tabl

Page 21 - Trademarks

IBM 1000VA and 1500VA LCD Tower UPS 9Figure 2. Front panel (showing System Status)The following functions are available on the control panel:System st