Step 5
Starting at the top of the following table, locate your symptom and perform the action
listed in the Action column.
Symptom Action
The power LED does not come on, or comes on
and does not stay on.
Check the power cable to the outlet. Check the
circuit breakers and check for power at the
outlet.
Ensure that the room temperature is within 60 -
90°F.
If you do not find a problem, record error code
M0PS0000 and report the problem to the
service organization.
The diagnostics are loaded and there was NO
beep heard from the system unit during the IPL
sequence.
Record error code M0SPK001.
The system stops with the Diagnostic Operating
Instructions displayed.
Go to “Step 6” on page 168.
The system stops with a prompt to enter a
password.
Enter the password. You are not allowed to
continue until a correct password has been
entered. When you have entered a valid
password, wait for one of the other conditions to
occur.
The system stops with a three-, four- or
eight-digit error code(s) displayed on the
console.
Record the error code(s) and report the problem
to the service organization.
The system login prompt is displayed. You may not have pressed the correct key or
you may not have pressed the key soon enough
when you were to indicate a Service Mode boot
of diagnostic programs. If this was the case,
start over at the beginning of this step.
If you are sure that you pressed the correct key
in a timely manner, go to Step 7.
The system does not respond when the
password is entered.
Go to "Step 7".